article Open access

Characterization of indeterminate breast lesions on B-mode ultrasound using automated machine learning models

  • Journal of medical imaging
  • SPIE
Research footprint

At a glance

Citations
5
References
18
Comments
0
Paper overview

Öz

Purpose: While mammography has excellent sensitivity for the detection of breast lesions, its specificity is limited. Adjunct screening with ultrasound may partially alleviate this issue but also increases false positives, resulting in unnecessary biopsies. Our study investigated the use of Google AutoML Vision (Mountain View, California), a commercially available machine learning service, to both identify and characterize indeterminate breast lesions on ultrasound. Approach: B-mode images from 253 independent cases of indeterminate breast lesions scheduled for core biopsy were used for model creation and validation. The performances of two sub-models from AutoML Vision, the image classification model and object detection model, were evaluated, while also investigating training strategies to enhance model performances. Pathology from the patient’s biopsy was used as a reference standard. Results: The image classification models trained under different conditions demonstrated areas under the precision–recall curve (AUC) ranging from 0.85 to 0.96 during internal validation. Once deployed, the model with highest internal performance demonstrated a sensitivity of 100% [95% confidence interval (CI) of 73.5% to 100%], specificity of 83.3% (CI = 51.6 % to 97.9%), positive predictive value (PPV) of 85.7% (CI = 62.9 % to 95.5%), and negative predictive value (NPV) of 100% (CI non-evaluable) in an independent dataset. The object detection model demonstrated lower performance internally during development (AUC = 0.67) and during prediction in the independent dataset [sensitivity = 75 % (CI = 42.8 to 94.5), specificity = 80 % (CI = 51.9 to 95.7), PPV = 75 % (CI = 50.8 to 90.0), and NPV = 80 % (CI = 59.3 % to 91.7%)], but was able to demonstrate the location of the lesion within the image. Conclusions: Two models appear to be useful tools for identifying and classifying suspicious areas on B-mode images of indeterminate breast lesions.

Record transparency

Publication details

DOI
10.1117/1.jmi.7.5.057002
OpenAlex
W3094239108
Document type
article
Language
EN
Source
Journal of medical imaging
Last metadata update
Community

Comments

Oturum Açın to join the discussion.

  1. No comments yet. Start the discussion.